# System

Technical documentation for the current Modular Rack Power design.

Canonical: https://mrps.karlquinsland.com/system/
Updated: 2026-09-19

Source: https://github.com/kquinsland/modular-rack-mount-power-system/blob/f4855f0c2ca8b85eb16c4d821fcad9c6971e39fe/site/content/system/_index.md


---


The core design principle of MRPS is to separate shared infrastructure from replaceable output modules in a scalable and modular manner.

1. At least one high current DC supply is wired to a [backplane](https://mrps.karlquinsland.com/system/hardware/backplane/).
2. The backplane  distributes the DC bus to six slots, measures aggregate current, powers local control electronics and fans.
3. Each [module](https://mrps.karlquinsland.com/system/hardware/modules/) mates with the backplane and occupies a slot. Each hosts a power-output module or accessory.
4. The backplane and every carrier have their own microcontroller to manage local peripherals and a CAN-FD transceiver to communicate with the rest of the system. CAN-FD is the only inter-board communication bus.

```text
DC input
   │
   ├── Backplane controller, current monitor, CAN-FD, and cooling
   │
   └── Shared VIN_BUS
          ├── Carrier 1 ── USB-C PD module
          ├── Carrier 2 ── Accessory or USB-C PD module
          ├── ...
          └── Carrier 6 ── USB-C PD module
```

This repo is going "live" with the second-generation backplane, which consolidates functions that previously lived on separate backplane and controller boards.

At least for _now_ there is only one "supported" carrier/module but there are plans to expand the range of compatible modules in the future.

## Current design targets

To make a very long story short, the first iteration of the design is targeting a DC input of _at most_ 30V, nominally somewhere around 24V.
This is because the [current/only carrier module](https://mrps.karlquinsland.com/system/hardware/modules/carrier/#sw3538-usb-c-pd-module) has a maximum input voltage of 30V.
Furthermore, the `SW3538` based module can't do more than 100 W without using non-standard configurations so the effective 'ceiling' here is going to be 100 W per port until a new module revision is introduced.

The only way to achieve 100W with USB-C/PD is to use [5A/20V (100W) configuration](https://en.wikipedia.org/wiki/USB_hardware#USB_Power_Delivery).

Just for perspective, a _good quality_ power supply that can do ~ 27v and ~ 30A will cost somewhere in the range of 200-400 USD so there's also a cost reason to keep things at or below the 100 W per port ceiling at this time.

Given all that:

| Property | Current target |
| --- | --- |
| Initial system input | Nominal 24-28 V DC |
| Module slots | Six |
| Initial USB-C policy ceiling | 20 V, 5 A, 100 W per port |
| Working aggregate input budget | Approximately 30 A |
| Cooling | Two independently switched 3-wire fans per backplane |

And so so so many additional properties that are "theoretical, untested" until I get the first physical articles in hand; they [have been ordered](/worklogs/2026/09/10-first-physical-prototypes/) and are expected to arrive soon.

Very early prototypes did put per-slot switching on the backplane but that was later abandoned in favor of a simpler, shared input bus design; the current design does not presently switch or limit each backplane slot.

Slot power is present whenever the shared input bus is energized due to the [limited number of pins](#carrier-slots) available on the connector.

For the underlying engineering record, see the repository's
[system overview](https://github.com/kquinsland/modular-rack-mount-power-system/blob/main/docs/system-overview.md).

## Interfaces

### System DC input

The backplane accepts ground and `VIN_RAW` through a user-installed two-position
terminal. The initial population targets a nominal 24 V source. After the
aggregate current shunt, the rail becomes `VIN_BUS` and feeds the backplane
converters and all six slots.

### External CAN-FD

The external connection exposes ground, CAN low, and CAN high. Connector-side
ESD protection and a common-mode choke protect this boundary. A normally-open
120 Ω termination option is intended only for installations where the
backplane sits at a physical end of the CAN bus.

### Carrier slots

Each combined power-and-signal connector carries:

| Contact | Signal | Purpose |
| ---: | --- | --- |
| 1 | `VIN_BUS` | Unswitched power from the backplane |
| 2 | `GND` | Power and signal return |
| 3 | `CANH` | Shared CAN-FD high |
| 4 | `CANL` | Shared CAN-FD low |

Each carrier includes its own connector-side CAN protection.
The backplane does not duplicate an ESD network at every slot.

### Backplane-local interfaces

- I²C connects only the backplane STM32 and aggregate INA237 current monitor.
- Two 3-wire fan headers provide ground, switched 12 V, and tachometer input.
- The external DS18B20 header provides ground, 1-Wire data, and 3.3 V.
- A Tag-Connect SWD footprint for programming and debugging the STM32.

Consult the engineering [interface tables](https://github.com/kquinsland/modular-rack-mount-power-system/blob/main/docs/interfaces.md) before relying on connector reference designators or fabricating hardware.

## Power and cooling

> [!WARNING]
> Everything below is theoretical.
> I have done some simulations and calculations to get a ballpark estimate but these numbers should not be taken as guaranteed performance.
> Once I have physical prototypes, I'll do some tests to validate these theoretical numbers.

### Initial operating budget

| Item | Working value |
| --- | ---: |
| Supply input | Nominal 24 V |
| USB-C output policy | Up to 20 V, 5 A, 100 W |
| Per-slot input budget | Approximately 4.7 A |
| Aggregate backplane target | Approximately 30 A |
| Aggregate current shunt | 1 mΩ |

At 30 A, the aggregate shunt develops about 30 mV and dissipates about 0.9 W.
The biggest thermal issue will be the copper traces on the backplane and the general topology - all the DC is supplied from one end of the backplane so there's a voltage drop and heating gradient along its length.

There is a [simple tool](https://github.com/kquinsland/modular-rack-mount-power-system/blob/main/scripts/pcb_power_capacity.py) to estimate voltage drop and heating along the backplane traces.

[![Backplane copper-capacity comparison showing layer geometry, current capacity along the bus, and estimated temperature rise for two copper stackups at 33 A](<https://mrps.karlquinsland.com/system/_files/backplane-power-cap.webp>)](<https://mrps.karlquinsland.com/system/_files/backplane-power-cap.webp>)

IPC-2221 screening estimate at 33 A total load, comparing 2 oz outer / 1 oz inner copper with 1 oz outer / 0.5 oz inner copper. These are calculated estimates, not measured results.


> [!NOTE]
> The figure above is a visual representation of the estimated voltage drop and heating along the backplane traces based on the initial operating budget.
> It is a _crude_ simulation and is NOT meant to be taken as precise or guaranteed.

### Local rails and cooling

The estimated 11 W loss from each fully loaded initial USB-C module makes forced-air cooling a design requirement rather than an optional feature.

To facilitate this, each backplane has a dedicated LM5164 converter for a 12V 1A rail meant to power the cooling fans.
The STM32 is meant to monitor temperature from a few different locations and drive the two fans as needed.

See the engineering [power budget](https://github.com/kquinsland/modular-rack-mount-power-system/blob/main/docs/power-budget.md) for conductor calculations and open protection questions.